Institutional Repository
    • Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   University of Economics & Technology Repository
  • Akademik Arşiv / Institutional Repository
  • Mühendislik Fakültesi / Faculty of Engineering
  • Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering
  • View Item
  •   University of Economics & Technology Repository
  • Akademik Arşiv / Institutional Repository
  • Mühendislik Fakültesi / Faculty of Engineering
  • Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Multi-Regional Adaptive Image Compression (AIC) for Hip Fractures in Pelvis Radiography

Thumbnail
Date
2017
Author
Nasıfoğlu, Hüseyin
Eroğul, Osman
Atac, Gokce Kaan
Özdemir, Galip
Metadata
Show full item record
Abstract
High resolution digital medical images are stored in DICOM (Digital Imaging and Communications in Medicine) format that requires high storage space in database. Therefore reducing the image size while maintaining diagnostic quality can increase the memory usage efficiency in PACS. In this study, diagnostic regions of interest (ROI) of pelvis radiographs marked by the radiologist are segmented and adaptively compressed by using image processing algorithms There are three ROIs marked by red, blue and green in every image. ROI contoured by red is defined as the most significant region in the image and compressed by lossless JPEG algorithm. Blue and green regions have less importance than the red region but still contain diagnostic data compared to the rest of the image. Therefore, these regions are compressed by lossy JPEG algorithm with higher quality factor than rest of the image. Non-contoured region is compressed by low quality factor which does not have any diagnostic information about the patient. Several compression ratios are used to determine sufficient quality and appropriate compression level. Compression ratio (CR), peak signal to noise ratio (PSNR), bits per pixel (BPP) and signal to noise ratio (SNR) values are calculated for objective evaluation of image quality. Experimental results show that original images can approximately be compressed six times without losing any diagnostic data. In pelvis radiographs marking multiple regions of interest and adaptive compression of more than one ROI is a new approach. It is believed that this method will improve database management efficiency of PACS while preserving diagnostic image content.
URI
https://doi.org/10.1007/978-981-10-4166-2_10
http://hdl.handle.net/20.500.11851/1791
Collections
  • Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 




by OpenAIRE

Browse

All of RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy Submit DateBy TypeKapsamWOSScopusPubMedTR-DizinAvrupa Birliği Destekli Yayın SayısıTÜBİTAK Destekli Yayın SayısıDilErişimThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Submit DateBy TypeKapsamWOSScopusPubMedTR-DizinAvrupa Birliği Destekli Yayın SayısıTÜBİTAK Destekli Yayın SayısıDilErişim

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Creative Commons License
Institutional Repository by TOBB ETU Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License..

Institutional Repository:



TOBB ETU için Devinim Yazılım Eğitim Danışmanlık tarafından özelleştirilerek kurulmuştur.